CX105 – Conductivity Transmitter, Loop-Powered 4-20mA

$745.26

CX105 - Conductivity Transmitter, Loop-Powered 4-20mA

Parameters & Applications

Product Information

Our CX105 conductivity transmitter is an isolated output 4-20mA industrial transmitter for reading contacting conductivity sensors. The CX105 transmitter also measures Resistivity and TDS. Easily power the unit with available two-wire power supply loop. This transmitter is ideal for connecting to a PLC for advanced control systems. The CX105 has versatile mounting options for wall or panel mount. With a dual display LCD, monitoring both the measuring value and the temperature is simple.

  • Dual display shows the measuring value and temperature
  • Compatible with a wide variety of contacting conductivity, resistivity, and TDS sensors
  • One year limited warranty
  • CE certified – compliant with European Community Standards

NOTE:  Transmitter is only compatible with sensors with tinned leads and Pt1000Ω RTD temperature compensation.

Our CX105 conductivity transmitter is an isolated output 4-20mA industrial transmitter for reading contacting conductivity sensors. The CX105 transmitter also measures Resistivity and TDS. Easily power the unit with available two-wire power supply loop. This transmitter is ideal for connecting to a PLC for advanced control systems. The CX105 has versatile mounting options for wall or panel mount. With a dual display LCD, monitoring both the measuring value and the temperature is simple.

  • Dual display shows the measuring value and temperature
  • Compatible with a wide variety of contacting conductivity, resistivity, and TDS sensors
  • One year limited warranty
  • CE certified – compliant with European Community Standards

Specifications

  • Display: LCD: 128*65 dot matrix, figure or alphabet: 12×8, 28×15, 32×18, etc.,

    Display Update rate: 1 second

    Display Contrast: User selected, 5 levels

    Measurement:

    • Conductivity: 0.05 to 500,000 μS/cm
    • Resistivity: 1KΩ•cm to 18.3MΩ•cm
    • TDS: 0.023 to 200,000 ppm
    • Accuracy: ± 0.5% of reading
    • Repeatability*: ± 0.05% of span
    • Temperature Drift*: Zero and Span: ± 0.02% of span per℃

    *These performance specifications are typical at 25°C

    Electrical:

    • Power: 19 -48VDC, regulated, 30mA maximum

    Current Output:

    • Isolated 4-20 mA output with 0.004 mA (12-bit) resolution
    • Update Rate: 1 second
    • Maximum Loop Impedance: 250Ω@24V; 600Ω@31V; 1500Ω@48V

    Memory:

    • Non-volatile: All user settings are retained indefinitely without battery backup

    Open-Collector Output:

    • Isolated, 40 VDC max. pull-up voltage

    The OC output can be configured to be one of three modes below:

    High mode, Low mode, Proportional pulses

    Ambient Conditions:

    • Operation: -10 °C to 70 °C (14 °F to 158 °F); 0-95% relative humidity, non-condensing
    • Transport/storage: -15°C to 80°C(5°F to 176°F); 0-95% relative humidity, non-condensing

     

    Standards and Approvals

    • CE: Certified Compliant to European Community Standards.

Downloads


Additional information

Weight 1.4 lbs
Dimensions 6.25 × 6 × 5 in