Login

Register

Login

Register

FREE U.S. SHIPPING ON ORDERS $199+ | 24-Hour Rapid Delivery Available
Product Selection Filter Tool / Showing 101 - 109 of 109 results
Product Type
Parameter
  • High Accuracy and Repeatability
    • Accuracy is 2% of reading with 1% repeatability*
    • Electro-polish finish provides excellent stability and consistency
    Multiple Cell Constants Cover Wide Range of Applications
    • 0.01/cm for ultra-pure/pure water
    • 0.1/cm for pure and drinking water
    • 1.0/cm for wastewater and process water
    Durable in High-Temperature and High-Pressure Environments
    • Built from 316 Stainless Steel and Teflon
    • Withstands up to 150° C (302° F) and 1379 KPA (200 PSIG)
    CA ResidentsProp 65 WARNING(S) *Accuracy and repeatability of the sensor depends on the accuracy of the calibrating electronics
  • chlorine dioxide maintenance kit
    Keep your chlorine dioxide amperometric sensors running for extended lifetime and improved accuracy using this chlorine dioxide maintenance kit. Compatible with CLD Series Chlorine Dioxide Amperometric Sensors. This kit includes:
    • (1) replacement membrane cap
    • (1) replacement pressure relief band
    • (2) 30mL bottles of electrolyte refill solution
    • (2) 10mL syringes
    • (3) polishing squares
  • chlorine dioxide sensor
    Our dependable chlorine dioxide sensor features amperometric measurement technology. Designed for use in disinfection applications. Sensor directly outputs a 4-20mA signal for easy control system integration. Maximize sensor lifetime by easily replacing membrane cap and fill solution (FCLA-5018). Use with FC72 Flow Cell is highly recommended. An optional flow meter (FM001 Flow Regulator) is available to provide consistent flow for added system stability.
    • Reliable amperometric sensor technology
    • Real time continuous measurement
    • Integrated automatic temperature compensation
    • Maximum sensor lifetime
    • One year limited warranty
  • The Calibration Box (PN# CALBOX - MB) is used to calibrate modbus sensors. The wires from the sensors connect to the terminal block on the front of the box. It connects to a computer via a USB interface. This product is to be used with only the integrated version of our Smart Sensors, which include:
    1. S272 pH & ORP sensors
    2. DO6400 Series sensors
    3. TCS3020 sensor
    4. FCL & CLD amperometric sensors
    The Calibration Box is not measurement specific. One of these can be used to calibrate all integrated sensors.
  • The Calibration Adapter (PN# S857) is used to calibrate modbus sensors. It threads on to the back of the smart sensor and it connects to a computer via a USB interface. This product is to be used with only the modular version of our Smart Sensors, which include:
    1. S8000 Series pH and ORP Sensors
    2. CS8000 Series Conductivity Sensors
    The Calibration Adapter is not measurement specific. One of these can be used to calibrate all modular sensors.
  • ph simulator
    pH and ORP measurement loops can be difficult to troubleshoot unless you have the right tools. Our CAL-C110 simulator mimics the signal of a perfect pH or ORP sensor. No need to throw away good sensors when the issue may be the interconnection cables or pH/ORP instrument. The simulator costs less than most pH or ORP sensors. It can easily pay for itself the very first time you consider disposing of a perfectly good sensor. Allows the user to identify the sensor, cable, meter, preamplifier, or controller as the cause of the problem.
    • An essential tool for troubleshooting pH and ORP systems
    • Compatible with most pH and ORP systems using BNC connectors
    • Simulate high impedance loads
    • Instantly ready for use and includes 9V battery
    • One year limited warranty
     
  • cpvc ball valve
    Our BV-1 full port 1” ball valve is designed for use with our S675 Series Wet Tap Insertion Assemblies and S656CD pH Sensors. The BV1 mounts a pH sensor in pressurized lines or the sidewall of tanks. Sensors can be retracted for service without shutting down lines or the need to empty tanks. Constructed of durable CPVC.
    • Remove sensors for cleaning and maintenance without system shutdown
    • Full 1" port design is compatible with Sensorex insertion assemblies and sensors
    • One year limited warranty
  • orp calibration solution
    Use this pre-mixed ORP calibration solution for verifying and calibrating ORP sensors.The solution standard is 228mV and is widely used for ORP sensor calibration. Supplied in a pint (16oz) bottle with long term stability.
    • Simple calibration of ORP sensors to known standard
    • Fast response time with all ORP sensors
    • No mixing required - solution is pre-mixed and instantly ready for use
    • One year shelf life guaranteed
  • ORP Calibration Solution with Quinhydrone
    The B125 ORP Calibration kit can be used for a simple calibration of both pH and ORP sensors. Use this kit for pH calibration, then convert the pH buffers into stable ORP buffers by saturating with quinhydrone. The B125 ORP calibration kit is a complete, ready-to-use package and can be used for up to 30 calibrations.
    • Simple calibration of pH and ORP simultaneously
    • Fast response time
    • Mix and prepare the calibration buffers in seconds
    • Instantly ready for use and ships with plastic beakers and stirring sticks