FREE U.S. SHIPPING ON ORDERS $199+ | 24-Hour Rapid Delivery Available
Product Selection Filter Tool / Installation Hardware & Accessories / Showing all 16 results
Product Type
Parameter
  • Our FC75C Flow Cell Kit is an easy and economical means for mounting pH sensors for in-line applications.  Compatible with all 12mm electrodes, including S222CD Light-Duty Online Process pH Sensor. To only purchase the gland, please purchase the FC75P
    Add to cart Details
  • FC800
    Add to cart Details
  • blind pH transmitter

    Now Available with optional MODBUS/RS485 Interface

    The EM802-EC is our most cost-effective solution for connecting our S8000 series Contacting Conductivity sensors to a PLC or SCADA system. This small electronic module functions as a blind transmitter with a 4-20mA or MODBUS/RS485 output. No additional instrumentation is required to condition the sensor signal to be read by your PLC or SCADA. It can also be used to pair Sensorex sensors with any controller that has a 4-20mA or RS485 input card. Easily connects to our CS8300TC Modular Contacting Conductivity Sensor Package to form a complete monitoring solution.
    • Blind 4-20mA or MODBUS/RS485 transmitter for connecting conductivity sensors to PLC or SCADA
    • Small form factor saves valuable panel space
    • Input Voltage Options:
      • 12V DC - MODBUS only
      • 24V DC - 4-20mA & MODBUS
    • Compatible with CS8300 conductivity sensor
    • Compatible with PT1000 RTD temperature compensation
    Select options Details
  • CPVC Flow Cell
    The FC875/T Threaded 3/4″ CPVC Flow Cell is used for in-line installation of the S8000CD Self-Cleaning Industrial pH Sensor or S8000CD-ORP Self-Cleaning Industrial ORP Sensor. The FC875/T is part of a complete S8000 package and can be purchased separately, or it is already included in our S8000 Kits listed below:
    Add to cart Details
  • Pipe mount kit
    The LPMA-002 is an accessory kit that allows pipe-mounting of the LPM100 loop-powered display meter. The LPM100 is a durable, loop-powered process meter for use in demanding applications. This rugged, large display meter can be mounted in various configurations and endure harsh environmental conditions. Simple installation and operation make it an ideal solution for process read out monitoring.
    • Durable for harsh environmental conditions
    • Simple set up and operation
    • User-friendly interface
    • Compatible with Sensorex 4-20mA output sensors
    • One year limited warranty
    Add to cart Details
  • S653 Cable Assembly
    With threading for submersion mounting, the S653 Cable Assembly is the perfect complement to our S651CD Submersible Electrode series. This cable assembly is designed to submerge the electrode in tanks, flumes and sewer lines. The cost-effective CPVC construction is well suited for most water and wastewater applications. Pairing the S653 Cable Assembly with an S651CD series Electrodes allows for quick electrode changes, drastically reducing downtime due to maintenance.
    • Use with one of our S651CD series Electrodes for quick and easy maintenance
    • Threading design for fast and simple installation
    • Durable CPVC design is suitable for most applications
    • One year limited warranty
    Select options Details
  • Hot Tap Insertion
    Users installing into large tanks, large process lines and scrubber lines will appreciate this hot tap assembly to simplify installation. Adjustable insertion depth up to 12” ensures sensor is in flow for best results. Designed in CPVC for a user friendly cost compared to expensive stainless models, the S675 assembly is well suited for most water and wastewater treatment applications. Incorporates optional automatic temperature compensation (ATC) with 1000Ω RTD. Supplied with 10 foot cable. Designed for use with our S656CD Flat Surface pH Cartridge and BV-1 Ball Valve to facilitate removal from system without need for shutdown.
    • Durable CPVC design is suitable for most applications
    • Remove sensors for cleaning and maintenance without system shutdown
    • Easy installation
    • One year limited warranty
    Select options Details
  • differential sensor salt bridge
    When chemicals from challenging applications get inside the sensor reference, chemical reactions can create insoluble salts. These salts clog the reference junction and interrupt the electrical circuit, leading to drifting measurements. Fortunately, our differential pH and ORP sensors can be maintained with the SDS replaceable reference junctions (salt bridges). Simply remove the old salt bridge and insert a new one to restore normal performance to a clogged sensor.
    • Replaceable reference junction for extending the lifetime of SD7000, SD7420, SD7500 sensors
    • Direct-fit compatibility for several popular Hach & Water Analytics models
    • One year limited warranty with the Sensorex Guarantee
    *Hach is a registered trademark of Danaher. Water Analytics is a registered trademark of Water Analytics. No affiliation, endorsement or sponsorship is stated or implied.
    Select options Details
  • pH Sensor Mounting Gland (3/4")
    Our FC75P Mounting Gland are an easy and economical means for mounting pH sensors for in-line applications.  Compatible with all 12mm electrodes, including S222CD Light-Duty Online Process pH Sensor. For Flow Tee See FC75c
    Add to cart Details
  • ATC cable assembly
    The 855 is a shielded, low-noise cable assembly for our S8000 series pH and ORP sensors with Automatic Temperature Compensation (ATC). This ATC cable assembly has 3/4" NPT thread for inline or submersion installations. Click this link for our shielded, low-noise cable assembly without temperature compensation (S853).
    Select options Details
  • ATC cable assembly
    The 855 is a shielded, low-noise cable assembly for our S8000 series pH and ORP sensors. This cable assembly has 3/4" NPT thread for inline or submersion installations. Click this link for our shielded, low-noise cable assembly with automatic temperature compensation ATC (S855).
    Select options Details
  • Free Chlorine Flow Cell
    Our FC72 flow cell facilitates high-accuracy measurements of free chlorine and chlorine dioxide by preventing air bubble formation on the sensor membrane while maintaining laminar flow across the membrane. Compatible with FCL Series Free Chlorine Sensors and CLD Series Chlorine Dioxide Sensors.
    • Facilitates high-accuracy measurements
    • Simple Sensor Installation
    • For use with Sensorex FCL Series Free Chlorine and CLD Series Chlorine Dioxide Sensors
    • One year limited warranty
    Add to cart Details
  • cpvc ball valve
    Our BV-1 full port 1” ball valve is designed for use with our S675 Series Wet Tap Insertion Assemblies and S656CD pH Sensors. The BV1 mounts a pH sensor in pressurized lines or the sidewall of tanks. Sensors can be retracted for service without shutting down lines or the need to empty tanks. Constructed of durable CPVC.
    • Remove sensors for cleaning and maintenance without system shutdown
    • Full 1" port design is compatible with Sensorex insertion assemblies and sensors
    • One year limited warranty
    Add to cart Details
  • water flow regulator
    Our FM001 Flow Regulator allows for simple flow control, and is recommended for use with the FCL Series Free Chlorine Sensors and CLD Series Chlorine Dioxide Sensors when integrated with the FC72 Flow Cell. Provides precision flow control from 0.1 to 1.0 gpm (0.5 to 4.0 l/min) with 94% accuracy (full-scale range).
    • Facilitates high-accuracy measurements of free chlorine and/or chlorine dioxide
    • Precision flow controlfrom 0.1 to 1.0 gpm
    • Simple installation
    • One year limited warranty
    Add to cart Details
  • sensor cartridge housing
    Sensor cartridge housing for use with S8000 series pH and ORP electrodes. Available with integrated automatic temperature compensation and solution ground. Reduce operating costs of pH sensors by using the modular S8000 platform - only the sensor cartridge must be replaced. For use in submersion or in-line installations.
    • Modular design lowers overall pH sensor cost
    • Easy installation
    • Solution ground available for eliminating measurement errors caused by reference ground potentials
    • Compatible with all Sensorex S8000 Series pH and ORP sensor cartridges
    • One year limited warranty
    Select options Details
  • electronic output modules

    Now Available with optional MODBUS/RS485 Interface

    For S8000 Modular pH, ORP and Contacting Conductivity applications which require more than a direct electrode output, plug-in electronic modules are available. Simply select the parameter type and desired amplifier/output.
    • Input Voltage Options:
      • 12V DC - MODBUS only
      • 24V DC - 4-20mA & MODBUS
    Select options Details